O3 Mining Inc. (TSX-V: OIII) (OTCQX: OIIIF) is pleased to announce that it has received the second set of assay results from its 24,505 metre drilling campaign completed between January 2024 and March 2024 on the Malartic H deposit within the Marban Alliance project, in Val-d’Or, Québec, Canada.
Highlights:
O3 Mining’s President and Chief Executive Officer, Mr. José Vizquerra commented: “The results from our exploration program at Malartic H continue to yield excellent intercepts. These intercepts represent the second set of assay results following the announcement of our initial positive assay results on April 17, 2024. Malartic H is consistently showing attractive results that increase the potential for growth laterally and at depth. Our team is currently completing additional drilling at Malartic H and we remain hopeful that this additional drilling could help support the quality and potential growth of the deposit. We are proud of the work completed to date at Malartic H which supports our belief in the robustness of the Marban Alliance Project and the Malartic H’s role in the project.”
The objective of the 2024 drilling campaign on the Malartic H deposit is the conversion of mineral resources that are currently classified as inferred mineral resources in the Corporation’s current mineral resource estimate to the indicated mineral resource category (see news release of O3 Mining dated June 20, 2023 and entitled “O3 Mining Delivers Maiden Mineral Resource Estimate for Malartic H“). The winter portion of the 2024 drilling campaign totaled 121 drill holes of which assay results for 42 drill holes are being reported today (including eight holes with partial results), the results for 56 drill holes were previously reported (see news release of O3 Mining dated April 17, 2024 and entitled “O3 Mining Intersects 119.1 g/t Au over 2.5 Metres at Malartic H, Marban Alliance“), and the results for 23 holes are still pending. After a pause during the spring breakup period, the drilling campaign has resumed with a short drilling program of 5,700 metres needed to complete the drill spacing of 40 metres necessary for the category conversion. The Corporation will report the outstanding assay results as they become available.
Malartic H Deposit
The Malartic H deposit has a recognized strike length of 950 metres, 300 metres wide and down to a vertical depth of 500 metres. It is located within five kilometres of the proposed processing plant described in the pre-feasibility study published on Marban Alliance in 2022 and approximately one kilometre to the north of the Malartic Hygrade former mine, near the hinge of a regional Z-shaped fold. The mineralized system is partially open laterally and completely open at depth. Notably, the Malartic H deposit is positioned between the northwestern extensions of the Marbenite and Norbenite shears, which host most of the resources of the Marban Alliance Project. At Malartic H, the two shears are northwest-trending and dipping around 70 degrees to the northeast. The deposit is hosted by an alternance of mafic and ultramafic volcanic sequence of the Jacola formation. Similar to the Hygrade area, numerous intermediate to felsic dyke systems are injected in the volcanic sequence. The mineralization occurs as disseminated pyrite with local visible gold in quartz veins and veinlets and disseminated in the host rock. Zones are spatially correlated shears within mafic volcanic units or with the intermediate to felsic dykes. All zones are roughly subparallel.
Figure 1: Photo of visible gold at 104.5 metres in hole O3MA-24-678 at Malartic H
Table 1: Drill Hole Intercepts at Malartic H. Only intercepts with metal factor above 5.0 (g/t Au x metres) are reported, cut-off 0.3 g/t Au and above 200 metres from surface. See Table 2 below for full technical parameters.
Hole | From (m) |
To (m) |
Vertical Depth (m) |
Grade (g/t Au) |
Core Length (m) |
Metal Factor (g/t Au x m) |
O3MA-24-578 | 5.4 | 19.1 | 7.6 | 1.7 | 13.7 | 23.1 |
O3MA-24-588 | 75.6 | 78.3 | 53.2 | 3.3 | 2.7 | 8.9 |
O3MA-24-611 | 51.3 | 58.1 | 37.3 | 1.3 | 6.8 | 8.6 |
O3MA-24-611 | 74.0 | 78.5 | 52.1 | 2.4 | 4.5 | 11.0 |
O3MA-24-620 | 59.0 | 69.4 | 55.8 | 0.9 | 10.4 | 9.4 |
O3MA-24-622A | 211.0 | 220.9 | 206.1 | 0.6 | 9.9 | 6.1 |
O3MA-24-634 | 61.8 | 63.0 | 61.9 | 5.8 | 1.2 | 7.0 |
O3MA-24-645 | 127.9 | 133.2 | 92.2 | 1.1 | 5.3 | 5.9 |
O3MA-24-651 | 54.8 | 62.0 | 40.4 | 0.7 | 7.2 | 5.1 |
O3MA-24-654 | 185.3 | 190.5 | 130.8 | 1.1 | 5.2 | 5.5 |
O3MA-24-655 | 69.2 | 84.6 | 52.7 | 3.0 | 15.4 | 45.5 |
O3MA-24-661 | 43.5 | 47.0 | 31.8 | 3.5 | 3.5 | 12.2 |
O3MA-24-666 | 98.1 | 107.2 | 77.3 | 0.8 | 9.1 | 7.6 |
O3MA-24-666 | 111.3 | 115.1 | 85.1 | 7.6 | 3.8 | 28.8 |
Including | 112.3 | 112.9 | 84.6 | 33.2 | 0.6 | 19.9 |
O3MA-24-668 | 31.9 | 34.6 | 22.6 | 2.5 | 2.7 | 6.7 |
O3MA-24-672 | 88.6 | 92.6 | 67.9 | 3.8 | 4.0 | 15.1 |
O3MA-24-674 | 152.6 | 153.4 | 131.3 | 7.4 | 0.8 | 6.0 |
O3MA-24-674 | 192.4 | 192.9 | 165.1 | 58.4 | 0.5 | 29.2 |
O3MA-24-675 | 78.4 | 94.4 | 87.5 | 1.7 | 16.0 | 26.5 |
Including | 78.4 | 79.2 | 79.9 | 12.3 | 0.8 | 9.8 |
O3MA-24-678 | 103.0 | 107.5 | 72.9 | 35.1 | 4.5 | 158.1 |
Including | 104.5 | 106.0 | 72.9 | 102.0 | 1.5 | 153.0 |
O3MA-24-678 | 207.4 | 215.3 | 145.9 | 1.4 | 7.9 | 11.1 |
O3MA-24-678 | 279.5 | 295.2 | 197.7 | 2.1 | 15.7 | 33.3 |
O3MA-24-678 | 299.5 | 318.8 | 212.4 | 2.1 | 19.3 | 40.9 |
Including | 310.1 | 310.8 | 213.3 | 31.7 | 0.7 | 22.2 |
O3MA-24-678 | 335.5 | 352.3 | 235.8 | 1.4 | 16.8 | 24.4 |
O3MA-24-678 | 388.7 | 396.1 | 268.3 | 3.3 | 7.4 | 24.1 |
O3MA-24-679 | 16.8 | 20.3 | 14.1 | 2.6 | 3.5 | 9.0 |
O3MA-24-682 | 12.8 | 21.0 | 11.5 | 0.9 | 8.2 | 7.7 |
O3MA-24-682 | 34.3 | 48.1 | 29.1 | 1.3 | 13.8 | 17.8 |
O3MA-24-682 | 101.0 | 107.5 | 73.9 | 1.0 | 6.5 | 6.5 |
O3MA-24-685 | 138.5 | 145.0 | 100.5 | 2.3 | 6.5 | 14.8 |
True width determination is currently unknown but is estimated at 65-80% of the reported core length interval for the zones. Assays are uncut except where indicated. |
Figure 2: Marban Alliance Project Map
Figure 3: Malartic H – Significant Intercepts Map
Table 2: Technical parameters of holes of the 2024 campaign at Malartic H that have received assay results
Hole | Azimuth (°) | Dip (°) | Start Depth (m) | End depth
(m) |
Length | UTM Zone 18 Easting (m) |
UTM Zone 18 Northing (m) |
Assays Status |
|
O3MA-24-549 | 224 | -45 | 0 | 141.3 | 141.3 | 275488 | 5339570 | All Received | |
O3MA-24-550A | 224 | -49 | 0 | 182.7 | 182.7 | 275596 | 5339618 | All Received | |
O3MA-24-551A | 215 | -81 | 0 | 129.2 | 129.2 | 275488 | 5339570 | All Received | |
O3MA-24-552 | 226 | -50 | 0 | 183.1 | 183.1 | 275484 | 5339510 | All Received | |
O3MA-24-553 | 224 | -50 | 0 | 158.6 | 158.6 | 275625 | 5339582 | All Received | |
O3MA-24-554A | 224 | -48 | 0 | 213 | 213 | 275521 | 5339495 | All Received | |
O3MA-24-555 | 224 | -45 | 0 | 126 | 126 | 275453 | 5339528 | All Received | |
O3MA-24-556 | 224 | -45 | 0 | 153 | 153 | 275410 | 5339496 | All Received | |
O3MA-24-557 | 224 | -50 | 0 | 189 | 189 | 275558 | 5339526 | All Received | |
O3MA-24-558 | 224 | -45 | 0 | 96 | 96 | 274904 | 5339951 | All Received | |
O3MA-24-559 | 224 | -55 | 0 | 225 | 225 | 275372 | 5339515 | All Received | |
O3MA-24-560 | 224 | -46 | 0 | 168 | 168 | 275593 | 5339450 | All Received | |
O3MA-24-561 | 224 | -45 | 0 | 96 | 96 | 274939 | 5339929 | All Received | |
O3MA-24-562 | 224 | -45 | 0 | 162 | 162 | 275565 | 5339478 | All Received | |
O3MA-24-563 | 63 | -85 | 0 | 108 | 108 | 275373 | 5339515 | All Received | |
O3MA-24-564 | 225 | -45 | 0 | 105 | 105 | 274985 | 5339922 | All Received | |
O3MA-24-565 | 224 | -55 | 0 | 180 | 180 | 275383 | 5339432 | All Received | |
O3MA-24-566A | 225 | -60 | 0 | 107.9 | 107.9 | 275605 | 5339351 | All Received | |
O3MA-24-567 | 224 | -45 | 0 | 106 | 106 | 275028 | 5339904 | All Received | |
O3MA-24-569 | 224 | -45 | 0 | 189.1 | 189.1 | 275374 | 5339457 | All Received | |
O3MA-24-570 | 224 | -46 | 0 | 180.1 | 180.1 | 275570 | 5339372 | All Received | |
O3MA-24-571 | 224 | -45 | 0 | 105 | 105 | 275060 | 5339878 | All Received | |
O3MA-24-572 | 225 | -55 | 0 | 108 | 108 | 275553 | 5339412 | All Received | |
O3MA-24-573 | 224 | -45 | 0 | 141.1 | 141.1 | 275329 | 5339417 | All Received | |
O3MA-24-574 | 224 | -45 | 0 | 105 | 105 | 275562 | 5339317 | All Received | |
O3MA-24-575 | 224 | -45 | 0 | 147 | 147 | 275101 | 5339918 | All Received | |
O3MA-24-576 | 224 | -45 | 0 | 143.6 | 143.6 | 275531 | 5339336 | All Received | |
O3MA-24-578 | 224 | -45 | 0 | 168 | 168 | 275120 | 5339880 | Partial | |
O3MA-24-579 | 224 | -50 | 0 | 170.6 | 170.6 | 275307 | 5339451 | All Received | |
O3MA-24-580 | 224 | -45 | 0 | 144 | 144 | 275514 | 5339371 | All Received | |
O3MA-24-581 | 224 | -45 | 0 | 137.9 | 137.9 | 275079 | 5339843 | All Received | |
O3MA-24-583 | 224 | -45 | 0 | 147 | 147 | 275492 | 5339396 | All Received | |
O3MA-24-584A | 224 | -45 | 0 | 123 | 123 | 275285 | 5339487 | All Received | |
O3MA-24-585 | 224 | -45 | 0 | 93 | 93 | 275017 | 5339842 | Partial | |
O3MA-24-587 | 224 | -45 | 0 | 90 | 90 | 275289 | 5339382 | All Received | |
O3MA-24-588 | 224 | -45 | 0 | 96 | 96 | 274987 | 5339864 | All Received | |
O3MA-24-589 | 224 | -50 | 0 | 174 | 174 | 275481 | 5339457 | All Received | |
O3MA-24-590 | 224 | -50 | 0 | 99 | 99 | 275270 | 5339416 | All Received | |
O3MA-24-591 | 224 | -45 | 0 | 96 | 96 | 274948 | 5339878 | All Received | |
O3MA-24-592 | 224 | -45 | 0 | 108 | 108 | 275184 | 5339503 | All Received | |
O3MA-24-593 | 224 | -45 | 0 | 216 | 216 | 275187 | 5339776 | Partial | |
O3MA-24-594 | 224 | -45 | 0 | 105 | 105 | 275222 | 5339483 | All Received | |
O3MA-24-595 | 252 | -45 | 0 | 188 | 188 | 275590 | 5339613 | Partial | |
O3MA-24-597 | 224 | -45 | 0 | 94.6 | 94.6 | 275243 | 5339449 | All Received | |
O3MA-24-598 | 214 | -63 | 0 | 231 | 231 | 275190 | 5339965 | All Received | |
O3MA-24-599 | 225 | -66 | 0 | 156 | 156 | 275020 | 5340267 | All Received | |
O3MA-24-600 | 224 | -45 | 0 | 102 | 102 | 275039 | 5339803 | All Received | |
O3MA-24-602 | 224 | -45 | 0 | 138.2 | 138.2 | 275081 | 5339786 | All Received | |
O3MA-24-603 | 224 | -45 | 0 | 213.2 | 213.2 | 275201 | 5339958 | All Received | |
O3MA-24-604 | 224 | -45 | 0 | 171.1 | 171.1 | 274987 | 5340286 | All Received | |
O3MA-24-606 | 234 | -55 | 0 | 198.1 | 198.1 | 275099 | 5340231 | Partial | |
O3MA-24-607 | 197 | -65 | 0 | 261 | 261 | 275201 | 5339958 | All Received | |
O3MA-24-609 | 210 | -52 | 0 | 162.2 | 162.2 | 275071 | 5340220 | All Received | |
O3MA-24-611 | 224 | -45 | 0 | 189 | 189 | 275160 | 5339920 | Partial | |
O3MA-24-612 | 224 | -45 | 0 | 221.9 | 221.9 | 275207 | 5339749 | All Received | |
O3MA-24-613 | 239 | -65 | 0 | 186 | 186 | 275154 | 5339953 | All Received | |
O3MA-24-614 | 224 | -45 | 0 | 110.8 | 110.8 | 274989 | 5340199 | All Received | |
O3MA-24-615 | 206 | -45 | 0 | 291.2 | 291.2 | 275172 | 5340092 | All Received | |
O3MA-24-617 | 239 | -80 | 0 | 207 | 207 | 275154 | 5339953 | All Received | |
O3MA-24-618 | 238 | -59 | 0 | 369 | 369 | 275512 | 5339760 | All Received | |
O3MA-24-619 | 224 | -45 | 0 | 201 | 201 | 275141 | 5339956 | All Received | |
O3MA-24-620 | 224 | -56 | 0 | 165 | 165 | 275095 | 5340185 | All Received | |
O3MA-24-621 | 223 | -46 | 0 | 162 | 162 | 275326 | 5339526 | All Received | |
O3MA-24-622A | 216 | -72 | 0 | 225 | 225 | 275119 | 5339999 | All Received | |
O3MA-24-623 | 228 | -46 | 0 | 216 | 216 | 275115 | 5340141 | All Received | |
O3MA-24-624 | 224 | -56 | 0 | 291 | 291 | 275512 | 5339760 | All Received | |
O3MA-24-626 | 238 | -67 | 0 | 237 | 237 | 275115 | 5340141 | All Received | |
O3MA-24-627 | 202 | -51 | 0 | 226 | 226 | 275471 | 5339696 | All Received | |
O3MA-24-628 | 224 | -45 | 0 | 183 | 183 | 275110 | 5339983 | All Received | |
O3MA-24-630 | 224 | -45 | 0 | 198 | 198 | 275073 | 5340113 | All Received | |
O3MA-24-634 | 228 | -85 | 0 | 204 | 204 | 275326 | 5339526 | All Received | |
O3MA-24-637 | 212 | -64 | 0 | 312 | 312 | 275419 | 5339755 | All Received | |
O3MA-24-641 | 224 | -45 | 0 | 159.1 | 159.1 | 275028 | 5340011 | All Received | |
O3MA-24-645 | 224 | -45 | 0 | 200.7 | 200.7 | 275069 | 5340051 | All Received | |
O3MA-24-647 | 225 | -70 | 0 | 165 | 165 | 275216 | 5339862 | All Received | |
O3MA-24-651 | 224 | -45 | 0 | 247.5 | 247.5 | 275275 | 5339698 | All Received | |
O3MA-24-652 | 224 | -45 | 0 | 174 | 174 | 274979 | 5340083 | All Received | |
O3MA-24-654 | 224 | -45 | 0 | 346 | 346 | 275298 | 5339941 | All Received | |
O3MA-24-655 | 224 | -45 | 0 | 178.1 | 178.1 | 275167 | 5339707 | All Received | |
O3MA-24-659 | 224 | -45 | 0 | 144.1 | 144.1 | 275221 | 5339538 | All Received | |
O3MA-24-661 | 224 | -45 | 0 | 144 | 144 | 275263 | 5339525 | All Received | |
O3MA-24-666 | 224 | -50 | 0 | 348 | 348 | 275368 | 5339727 | Partial | |
O3MA-24-668 | 224 | -45 | 0 | 126 | 126 | 275184 | 5339558 | All Received | |
O3MA-24-670 | 224 | -45 | 0 | 96 | 96 | 275144 | 5339517 | All Received | |
O3MA-24-671 | 224 | -46 | 0 | 168 | 168 | 275481 | 5339614 | All Received | |
O3MA-24-672 | 224 | -45 | 0 | 180 | 180 | 275725 | 5339392 | All Received | |
O3MA-24-673 | 224 | -45 | 0 | 114 | 114 | 275150 | 5339580 | All Received | |
O3MA-24-674 | 224 | -60 | 0 | 273 | 273 | 275327 | 5339635 | All Received | |
O3MA-24-675 | 224 | -77 | 0 | 177 | 177 | 275481 | 5339614 | All received | |
O3MA-24-676 | 252 | -47 | 0 | 246 | 246 | 275460 | 5339589 | All Received | |
O3MA-24-677 | 224 | -50 | 0 | 129 | 129 | 275113 | 5339603 | All Received | |
O3MA-24-678 | 224 | -45 | 0 | 405 | 405 | 275382 | 5339908 | All Received | |
O3MA-24-679 | 226 | -47 | 0 | 222 | 222 | 275460 | 5339589 | All Received | |
O3MA-24-680 | 202 | -50 | 0 | 235 | 235 | 275327 | 5339635 | All Received | |
O3MA-24-681 | 245 | -47 | 0 | 231 | 231 | 275598 | 5339669 | All Received | |
O3MA-24-682 | 224 | -45 | 0 | 201 | 201 | 275233 | 5339658 | All Received | |
O3MA-24-684 | 224 | -45 | 0 | 150 | 150 | 275670 | 5339384 | All Received | |
O3MA-24-685 | 224 | -50 | 0 | 240.1 | 240.1 | 275280 | 5339648 | Partial |
Qualified Person
The scientific and technical content of this news release has been prepared, reviewed, and approved by Mrs. Élise Bourgault, Geo (OGQ #894), Exploration Manager of O3 Mining, who is a “qualified person” within the meaning of National Instrument 43-101 – Standards of Disclosure for Mineral Projects.
Quality Assurance/Quality Control
Intercepts occur within geological confines of major zones but have not been correlated to individual vein domains at this time. Half-core samples are shipped to Agat Laboratory located in Val-d’Or, Québec, and Mississauga, Ontario, for assaying. The core is crushed to 75% passing -2 mm (10 mesh), a 250 g split of this material is pulverized to 85% passing 75 microns (200 mesh) and 50 g is analyzed by Fire Assay (FA) with an Atomic Absorption Spectrometry (AAS) finish. Samples assaying >10.0 g/t Au are re-analyzed with a gravimetric finish using a 50 g charge.
Commercial certified standard material and blanks are systematically inserted by O3 Mining’s geologists into the sample chain after every 18 core samples as part of the quality assurance and quality control program. Third-party assays are submitted to other designated laboratories for 5% of mineralized samples. Drill program design, QA/QC, and interpretation of results are performed by qualified persons employing a QA/QC program consistent with NI 43-101 and industry best practices.
About O3 Mining Inc.
O3 Mining Inc. is a gold explorer and mine developer on the road to produce from its highly prospective gold camps in Québec, Canada. O3 Mining benefits from the support and expertise of a team of industry leaders as it grows towards becoming a gold producer with several multi-million-ounce deposits in Québec.
O3 Mining is well-capitalized and owns a 100% interest in all its properties (107,000 hectares) in Québec. O3 Mining trades on the TSX Venture Exchange (TSXV: OIII) and OTC Markets (OTCQX: OIIIF). The Corporation is focused on delivering superior returns to its shareholders and long-term benefits to its stakeholders.
Red Pine Exploration Inc. (TSX-V: RPX) (OTCQB: RDEXF) is pleased ... READ MORE
F3 Uranium Corp. (TSX-V: FUU) (OTC Pink: FUUFF) is pleased to ann... READ MORE
Collective Mining Ltd. (NYSE: CNL) (TSX: CNL) is pleased to ann... READ MORE
Aris Mining Corporation (TSX: ARIS) (NYSE-A: ARMN) announces t... READ MORE
Staffing in place and operations shakedown underway Rare E... READ MORE