The Prospector News

Power Metallic Expands the Lion Zone with Deepest Assayed Intersection to Date and Delivers Initial Ni/Cu Assays from the Tiger Zone

You have opened a direct link to the current edition PDF

Open PDF Close
Slider

Share this news article

Power Metallic Expands the Lion Zone with Deepest Assayed Intersection to Date and Delivers Initial Ni/Cu Assays from the Tiger Zone

 

 

 

 

 

Power Metallic Mines Inc(TSX-V: PNPN) (OTCBB: PNPNF) (Frankfurt: IVV) is pleased to announce the return of 6 holes from the fall 2024 drilling campaign. Four holes were testing multiple target areas in the Lion zone (holes PN-24-086, 087, 092, 093), and two holes tested the Tiger target (PN-24-090 and 094).

 

Lion Zone (Figure 1)

Hole PN-24-092 and PN-024-093 tested the eastern edge of the interpreted plunge of the Lion zone, with PN-24-093 providing the deepest assayed intersection to date. Both holes confirmed the location of the eastern plunge extent of the Lion Zone (Figure 2, Table 1). Power Nickel previously released photos of mineralized core from hole PN-25-096 (news release February 5, 2025) located in the interpreted core of the Lion Zone and we are still awaiting assays for that hole (Table 1). Subsequent drilling below PN-25-096 has also returned significant visible mineralization including massive Cu/Ni zones in holes PML-25-001 and PML-25-002 (Figure 2) which are also pending assays to confirm grades.

 

Drill holes PN-24-086 and PN-24-087 were designed to fill in gaps in the Lion model to confirm the near surface eastern strike extension of the interpreted deposit. Both holes intersected the zone and returned high PGE values, including 1.55m @ 65.09 g/t Pd in PN-24-086 (Table 1, Figure 2).

 

Borehole EM (BHEM) has become the primary tool for discovery of more mineralization. Interpretation of BHEM results and improved interpretations of ground and airborne EM and magnetic surveys has been conducted by Hardrock Geophysics Inc., a group experienced in conducting geophysical surveys on polymetallic deposits. Identified BHEM conductors have to date consistently indicated sulphides in follow-up drilling. Previously identified conductors west of Lion (PN-24-082 to 085, see NR March 17, 2024) are currently being tested with drilling and have the potential of identifying a parallel sulphide zone to the west of Lion.

 

Table 1: Significant assay results from this news release – Lion zone

 

Hole From
(m)
To
(m) 
Length
(m)
Au
(g/t)
Ag
(g/t)
Cu
(%)
Pd
(g/t)
Pt
(g/t)
Ni
(%)
CuEq1
(%)
PN-24-086 52.90 76.00 23.10 0.14 4.52 0.31 4.70 0.01 0.02 2.08
including 65.45 75.00 9.55 0.16 4.68 0.50 11.27 0.01 0.03 4.60
including 65.45 67.00 1.55 0.24 4.46 0.51 65.09 0.00 0.05 23.76
PN-24-087 80.00 103.20 23.20 0.26 5.10 0.21 0.50 0.44 0.02 0.72
including 99.00 103.00 4.20 0.84 5.30 0.29 2.36 2.37 0.05 2.48
PN-24-092 461.10 472.70 11.60 0.07 2.61 0.37 0.92 0.31 0.07 0.93
including 463.75 475.75 2.00 0.16 10.00 1.72 4.17 1.02 0.13 3.60
PN-24-093 534.10 565.15 31.05 0.13 2.74 0.37 1.16 0.18 0.09 1.06
including 537.35 541.00 3.65 0.24 9.22 1.21 4.76 0.81 0.13 3.39
including 562.05 565.15 3.10 0.76 11.35 1.91 4.62 0.27 0.08 4.01
Note: Reported length is downhole distance; true width based on model projections is estimated as 85% of downhole length

 

Tiger Zone (Figure 1)

Hole PN-24-90 and PN-24-94 were drilled to test a weak airborne EM anomaly 700 meters northeast of Lion (Tiger Zone). Hole PN-24-090 appeared to miss the source of the airborne anomaly but returned multiple narrow zones of Cu, PGE, Au, Ag, +/-Ni (Table 2) confirming the presence of a mineralized structure.

 

A follow-up borehole EM survey (BHEM) completed in hole PN-24-090 confirmed an off-hole conductor which was drilled with hole PN-24-094 and intersected narrow zones of massive Ni/Cu sulphides (Table 2). Subsequent drill holes based on BHEM on the Tiger target (PN-25-098, 099 and 101) all intersected additional narrow Ni/Cu massive sulphides (assaying pending).

 

The Tiger zone is interpreted to be mobilized sulphides originating from a proximal ultramafic source rock and emplaced in the footwall paragneiss. To date drilling is still too sparse to model Tiger, but cross-section interpretation indicates that PN-24-090 was stopped just short of intersecting the higher grade Ni/Cu zones that were intersected in hole PN-24-094. BHEM conductors interpreted from hole PN-24-090 correctly vectored hole PN-24-094 to the source of the anomaly.

 

Subsequent BHEM on the later holes at Tiger have indicated further off-hole conductors that need to be tested. It is not known for certain what causes these off-hole conductors, but to date all previous drill testing of BHEM conductors has resulted in sulphide intersections, so it is reasonable to expect that sulphide concentrations are causing these untested anomalies.

 

Table 2: Significant assay results from this news release – Tiger zone

 

Hole From
(m)
To
(m) 
Length
(m)
Au
(g/t)
Ag
(g/t)
Cu
(%)
Pd
(g/t)
Pt
(g/t)
Ni
(%)
Co
(%)
CuEq1
(%)
PN-24-090 123.50 125.25 1.75 0.41 4.89 0.37 0.26 0.06 0.13 0.01 1.01
and 137.50 139.50 2.00 0.01 3.60 0.37 0.28 0.11 0.16 0.01 0.84
and 200.00 201.20 1.20 0.01 0.95 0.14 0.59 0.05 0.19 0.01 0.78
PN-24-094 192.50 202.40 9.90 0.02 1.41 0.24 0.73 0.08 0.57 0.03 1.77
including 192.50 195.00 2.50 0.04 2.34 0.46 1.23 0.21 0.92 0.04 2.95
including 200.20 202.40 2.20 0.01 2.72 0.51 1.87 0.12 1.53 0.07 4.50
Note: Reported length is downhole distance; true width based on model projections is estimated as 85% of downhole length

 

Previously released results are included at the end of this news release (Table 2).

Table 1: Significant assay results from this news release – Lion zone

 

1Copper Equivalent Rec Calculation

 

CuEq Rec represents CuEq calculated based on the following metal prices (USD) : 2,360.15 $/oz Au, 27.98 $/oz Ag, 1,215.00 $/oz Pd, 1000.00 $/oz Pt, 4.00 $/lb Cu, 10.00 $/lb Ni and 22.50 $/lb Co., and a recovery grade of 80% for all commodities, consistent with comparable peers.

 

Qualified Person

Joseph Campbell, P.Geo, VP Exploration at Power Metallic, is the qualified person who has reviewed and approved the technical disclosure contained in this news release.

 

About Power Metallic Mines Inc.

 

Power Metallic is a Canadian exploration company focusing on developing the High-Grade Nickel Copper PGM, Gold and Silver Nisk project into Canada’s next poly metallic mine.

 

On February 1, 2021, Power Metallic (then called Chilean Metals) completed the acquisition of its option to acquire up to 80% of the Nisk project from Critical Elements Lithium Corp. (CRE: TSXV).

 

The NISK property comprises a large land position (20 kilometres of strike length) with numerous high-grade intercepts. Power Metallic is focused on expanding the high-grade nickel-copper PGM, Gold and Silver mineralization with a series of drill programs designed to evaluate the initial Nisk discovery zone, the Lion discovery zone and to explore the land package for adjacent potential poly metallic deposits.

 

In addition to the Nisk project, Power Metallic owns significant land packages in British Colombia and Chile. Power Metallic has reorganized these assets in a related public vehicle through a plan of arrangement.

 

Neither the TSX Venture Exchange nor its Regulation Services Provider accepts responsibility for the adequacy or accuracy of this release.

 

 

Table 3: Significant assay results previously reported – Fall 2024 – Lion zone
Hole From To Length Au Ag Cu Pd Pt Ni CuEq
Rec*
(m) (m) (m) (g/t) ( g/t ) ( %) (g/t) ( g/t ) ( %) ( %)
PN-24-063 428 433 5 0.48 24.82 4.41 0.21 6.15 0.47 5.93
Including 429 432 3 0.73 37.9 7.1 0.3 9.26 0.5 9.3
PN-24-064 452 454.15 2.15 0.21 2.98 0.49 0.68 0.24 0.1 0.87
Including 452 453 1 0.27 3.9 0.85 1.03 0.31 0.19 1.35
PN-24-065 No significant values
PN-24-066 402 414 12.05 0.09 4.53 0.65 6.39 0.3 0.06 2.97
Including 411 414 3 0.2 12.5 1.95 2.26 0.62 0.12 2.78
With 413 414 1 0.28 32.4 5.08 4.44 0.44 0.16 6.22
PN-24-067 430.8 442.9 12.15 0.12 8.54 1.75 1.99 0.36 0.14 2.36
Including 430.8 433.4 2.65 0.16 8.47 1.27 1.01 0.84 0.11 1.8
With 431.9 432.35 0.5 0.77 43.1 6.38 1.46 4.24 0.38 7.74
and Including 440.6 442.9 2.35 0.31 32.77 7.41 8.59 0.64 0.32 9.64
With 442.2 442.9 0.75 0.34 70 15.7 12.7 0.49 0.41 18.01
PN-24-068 474.6 476.3 1.7 0.28 10.96 2.74 3.47 1.54 0.1 4.15
Including 474.6 475.1 0.5 0.94 36.3 8.55 11.4 5.19 0.28 13.34
PN-24-069 100 117 17 0.28 9.52 0.93 7.19 1.66 0.05 4.05
Including 100 106 6 0.42 19.33 0.96 11.68 3.69 0.04 6.43
With 100 102 2 0.66 47.3 2.15 19.35 2.87 0.08 10.26
and Including 112 117 5 0.35 7.8 1.78 9.69 0.74 0.09 5.38
With 114 115 1 0.57 12.9 6.09 33.8 0.85 0.36 18.39
PN-24-070 118 150 32 0.45 20.93 3.62 8.1 2.47 0.18 6.97
Including 120 130 10 0.5 12.94 1.76 10.82 5.98 0.08 7.44
With 120 12 2 0.53 28.2 5.77 7.61 1.86 0.25 8.45
and Including 138.6 150 11.4 0.6 44.51 8.39 11.52 1.24 0.42 11.94
With 141.4 147.4 6 0.79 60.98 12.9 15.21 1.6 0.51 17.22
PN-24-071 157 196.6 39.6 0.38 19.57 2.62 3.37 0.8 0.13 4.19
Including 157 160 3 0.25 8.93 0.68 6.2 0.04 0.02 3.04
and Including 185 196.6 11.6 0.88 49.9 8.25 9.57 2.64 0.34 12.46
With 193 196.6 3.6 1.56 63.03 10.39 11.42 7.9 0.32 16.89
PN-24-072 294 345 51 0.54 9.1 1.01 0.06 1.14 0.53 1.94
Including 294 299.2 5.2 0.18 3.67 0.02 0 1.19 0.89 0.86
and Including 307.9 309.75 1.9 0.45 4.43 0.11 0 0.99 0.71 0.99
and Including 321 323 2 0.15 3.45 0.32 0.03 1.18 0.51 1
and Including 325.4 332.5 7.1 0.68 18.14 0.66 0.08 0.73 0.15 1.61
and Including 332.5 345 12.5 0.31 16.22 3.01 0.17 3.14 1.49 4.63
With 332.5 337 4.5 0.53 32.71 6.4 0.35 5.73 3.74 9.59
PN-24-073 354.7 383.75 29.1 0.25 4.97 0.51 1.52 0.7 0.06 1.49
Including 366.9 368.95 2.1 0.21 20.67 3.53 4.05 0.1 0.27 5.14
and Including 376.3 379.25 3 1.67 14.93 0.89 10.36 5.71 0.04 7.41
PN-24-074 290 313.55 23.55 0.15 3.06 0.6 0.11 0.13 0.02 0.89
Including 294.8 295.8 1 0.09 7.2 0.5 0.02 0.93 0.02 0.9
and Including 311.1 313.55 2.5 1.27 18.57 5.1 0.52 0.78 0.13 6.46
PN-24-075 321.5 340.7 19.2 0.14 5.45 1.04 0.05 1.22 0.53 1.65
Including 321.5 324.9 3.4 0.6 13.02 0.24 0.01 3.38 3.6 2.97
and Including 330.3 331 0.75 0.27 15.4 1.94 0.06 0.52 0 2.16
and Including 337.7 340.7 3.05 0.23 15.29 5.31 0.23 4.36 0.27 6.62
PN-24-076 No significant values
PN-24-078 157.6 187 29.4 0.53 11.95 1.15 1.08 0.36 0.06 2.34
Including 157.6 169.15 11.55 0.44 11.55 0.59 1.25 0.76 0.02 1.92
With 158.6 160.6 2 0.64 14.85 0.49 2.71 2.32 0.02 3.24
And With 163.5 168.15 4.65 0.59 15.83 0.97 1.25 0.5 0.04 2.38
and Including 173.7 187 13.35 0.77 15.86 1.98 1.29 0.14 0.12 3.43
With 173.7 176.55 2.9 3.16 21.62 5.84 4.72 0.44 0.48 11.03
And With 183 187 4 0.23 35.78 2.3 0.73 0.11 0.03 3.23
PN-24-079 177 197 20.05 0.88 23.2 2.36 3.3 0.53 0.14 4.29
including 186.8 197 10.25 1.28 33.1 3.7 4.63 0.34 0.2 6.26
and 204.8 206.7 1.9 2.73 43.2 1.15 0.42 0.07 0.04 3.41
and 216.8 220 3.25 0.14 8.6 0.4 0.04 0.01 0.01 0.52
PN-24-080 Isolated individual assay values
PN-24-081 348.2 353 4.85 0.65 6.7 0.32 2.1 0.76 0.06 1.84
including 349 350 1 2.84 27.8 1.04 8.77 3.11 0.06 7.15
and 358.3 359.2 0.95 0.05 7.4 1.15 0.22 0.01 0.13 1.35
PN-24-082 Isolated individual assays – BHEM targeting hole
PN-24-083 Isolated individual assays – BHEM targeting hole
PN-24-084 Isolated individual assays – BHEM targeting hole
PN-24-085 Isolated individual assays – BHEM targeting hole
PN-24-088 Isolated individual assays – BHEM targeting hole
PN-24-095a 427 446.2 19.4 0.14 10.8 2.63 2.97 0.25 0.09 4.29
including 437.9 443.2 5.35 0.24 31.8 8.11 8.25 0.8 0.27 10.6

 

 

QAQC and Sampling

 

GeoVector Management Inc is the Consulting company retained to perform the actual drilling program, which includes core logging and sampling of the drill core.

 

All samples were submitted to and analyzed at Activation Laboratories Ltd, an independent commercial laboratory for both the sample preparation and assaying. Actlabs is a commercial laboratory independent of Power Metallic with no interest in the Project. Actlabs is an ISO 9001 and 17025 certified and accredited laboratories. Samples submitted through Actlabs are run through standard preparation methods and analysed using RX-1 (Dry, crush (< 7 kg) up to 80% passing 2 mm, riffle split (250 g) and pulverize (mild steel) to 95% passing 105 μm) preparation methods, and using 1F2 (ICP-OES) and 1C-OES – 4-Acid near total digestion + Gold-Platinum-Palladium analysis and 8-Peroxide ICP-OES, for regular and over detection limit analysis. Pegmatite samples are analyzed using UT7 – Li up to 5%, Rb up to 2% method. Actlabs also undertake their own internal coarse and pulp duplicate analysis to ensure proper sample preparation and equipment calibration.

 

GeoVector’s QAQC program includes regular insertion of CRM standards, duplicates, and blanks into the sample stream with a stringent review of all results. QAQC and data validation was performed and no material errors were observed.

 

 


Figure 1: Location map of drill holes referred to in this news release for the Lion and Tiger Zones (CNW Group/Power Metallic Mines Inc.)

 

 

 


Figure 2: Longitudinal view across the Lion Zone Area, presenting the CuEq Rec1 x meters, with interpreted plunge direction extension (CNW Group/Power Metallic Mines Inc.)

 

Posted March 25, 2025

Share this news article

MORE or "SLIDER"


Rick Mills – “Deciphering Max Resources' plan to Maximize Shareholder Value”

Max Resource Corp. (TSX-V:MAX) focused much of the last five years build... READ MORE

March 28, 2025

Jeff Clark - OUTRUNNING AN AVALANCHE! NEW PAYDIRT PODCAST WITH REVIVAL GOLD CEO HUGH AGRO

A fantastic new episode with CEO Hugh Agro of Revival Gold that begins with a s... READ MORE

March 27, 2025

StrikePoint Gold: Investor Update Video

While we’re wrapping up our drilling at the Hercules project near Reno, here... READ MORE

March 27, 2025

Prospector Podcast - Mike McGlone: Copper and Gold Flashing Warning Signs

On this episode, Mike McGlone, Chief Commodities Analyst at Bloomberg, d... READ MORE

March 26, 2025

NioBay Announces a New Member to Its Board of Directors

NioBay Metals Inc. (TSX-V: NBY) (OTCQB: NBYCF) is pleased to announce th... READ MORE

March 26, 2025

Copyright 2025 The Prospector News